    "variant": "A",
    "interior_area_m2": 180,
    "additional_interior_area_m2": 0,
    "seats": 100,
    "seat_loss": 0,
    "tables": 18,
    "solo_desks": 0,
    "boundary_footprint_m2": 2.654,
    "unobstructed_floor_including_seat_gaps_m2": 130.76321062174156,
    "seat_wall_intersections": [],
    "seat_pose_errors": [],
    "reachable_seat_approaches": 100,
    "unreachable_seats": [],
    "visibility_counts": {
      "clear": 33,
      "through-glass": 52,
      "blocked": 15
    },
    "route_assumptions": "50mm grid, 600mm walking disc, doors assumed operable/open for access. Final chair approach tests 240mm corridor only; not an accessibility or egress compliance result.",
    "fixed_reference_xy_m": [
      9.0,
      5.05
    ],
    "scent_transport": "Existing fixed geometry solver is not applied to B/C"
  },
  {
    "variant": "B",
    "interior_area_m2": 180,
    "additional_interior_area_m2": 0,
    "seats": 72,
    "seat_loss": 28,
    "tables": 15,
    "solo_desks": 0,
    "boundary_footprint_m2": 1.6929329813767375,
    "unobstructed_floor_including_seat_gaps_m2": 141.61089814370783,
    "seat_wall_intersections": [],
    "seat_pose_errors": [],
    "reachable_seat_approaches": 72,
    "unreachable_seats": [],
    "visibility_counts": {
      "clear": 72,
      "through-glass": 0,
      "blocked": 0
    },
    "route_assumptions": "50mm grid, 600mm walking disc, doors assumed operable/open for access. Final chair approach tests 240mm corridor only; not an accessibility or egress compliance result.",
    "fixed_reference_xy_m": [
      9.0,
      5.05
    ],
    "scent_transport": "Existing fixed geometry solver is not applied to B/C"
  },
  {
    "variant": "C",
    "interior_area_m2": 180,
    "additional_interior_area_m2": 0,
    "seats": 56,
    "seat_loss": 44,
    "tables": 10,
    "solo_desks": 4,
    "boundary_footprint_m2": 3.1696000000000004,
    "unobstructed_floor_including_seat_gaps_m2": 147.02141177360156,
    "seat_wall_intersections": [],
    "seat_pose_errors": [],
    "reachable_seat_approaches": 56,
    "unreachable_seats": [],
    "visibility_counts": {
      "clear": 56,
      "through-glass": 0,
      "blocked": 0
    },
    "route_assumptions": "50mm grid, 600mm walking disc, doors assumed operable/open for access. Final chair approach tests 240mm corridor only; not an accessibility or egress compliance result.",
    "fixed_reference_xy_m": [
      9.0,
      5.05
    ],
    "scent_transport": "Existing fixed geometry solver is not applied to B/C"
  }
]